On this page
Key fact Detail
- Chamber
- SS 316L, at negative pressure
- Inlet air
- H14 HEPA filtration
- Exhaust air
- Double HEPA filtration
- Glove ports in the standard configuration
- 4 on the main chamber, 2 on the pass box
- Tablet discharge
- Split butterfly valve, into IBC bins or polybags
What we supply: a sealed chamber around your tablet press
Fabtech's tablet compression isolator is a sealed SS 316L chamber around your tablet press.
The chamber runs at negative pressure. This means the air pressure inside is lower than in the room.
If the barrier is breached, air moves in and the powder stays inside.
HEPA filters are high-efficiency filters that stop very small particles. Inlet air passes through H14 HEPA filtration.
Exhaust air passes through double HEPA filtration. Where the compound needs it, the exhaust also passes through an inline exhaust scrubber before the air leaves.
A scrubber is a unit that cleans the exhaust air.
The tablet press is integrated into the isolator. It does not stand next to it.
Glove ports are sealed gloves fixed in the isolator wall. Operators use them to reach the machine for adjustment, sampling and change parts.
Material enters and leaves through a pass box or antechamber, which is a small sealed transfer chamber.
Discharge is the step most containment designs get wrong. Discharge means taking the tablets out.
The tablets must leave a negative-pressure enclosure and go into a bin without opening the barrier. Fabtech uses a Split Butterfly Valve to dispense into IBC bins or polybags.
The valve has two halves, and the transfer stays closed on both halves. Waste leaves through a dedicated waste liner port with a bag discharge.
Specifications
- Robustly constructed in SS 316L, with H14 HEPA filtration on inlet air and double HEPA filtration on exhaust
- Optional room air intake and dedicated air handling unit for temperature and humidity management
- Safe changing of HEPA filters
- Inline exhaust scrubber for exhaust air treatment
- Customisable ergonomics
- Standard configuration: one pass box with 2 glove ports, main chamber with 4 glove ports, and a glove integrity tester
- Multiple chamber configuration options available
- Optional CIP in the chamber
- Enclosed dispensing into blender bins or product containers
- Transfer routes through RTP
- In-situ chamber washing and drying, with drain collection cachepot for safe handling
- Waste liner port for waste bag discharge
- PLC-operated drum loader
- Password protection for different authorisation levels
- Optional IPC SCADA 21 CFR Part 11 for high-grade integration and compliance

Cleaning between products
A containment isolator around a press must be cleaned to a residue limit.
This limit comes from the compound's exposure limit. It is not enough for the isolator to look clean.
In-situ washing and drying is built in. In-situ means the chamber is washed and dried in place.
A drain collection cachepot collects the wash liquid. The liquid is then handled as contaminated waste.
It is not sent to the drain.
In a suite that makes more than one product, cleaning decides how long each changeover takes. So the cleaning method should be part of the specification from the start.
It should not be worked out after installation.
Containment level and how it is proved
The OEB band sets what the enclosure must achieve.
At OEB 4 and OEB 5, four things become stricter together: the transfer method, the glove specification, the cleaning method and the testing.
At that level, only one thing counts as proof: surrogate testing after installation. In this test, a safe powder stands in for the real compound, and the amount that escapes is measured.
A figure on a datasheet does not prove it.
An OEL (occupational exposure limit) is the highest amount of a compound in the air that a worker may be exposed to. Our guides explain OELs and how the limit is derived and surrogate testing for OEL validation in detail.

FAQ
What is the function of a tablet compression isolator?
It encloses the tablet press to contain the dust. This protects the operator. Where required, it also gives an aseptic environment, which means an environment free from microbes. This protects the product.
Can a tablet compression machine be fully integrated with an isolator?
Yes, full integration of the press with the isolator is standard. It is not an optional extra. A press that stands outside the barrier is not contained.
Are tablet compression isolators customisable to different press models?
Yes. Fabtech isolators are custom-designed to fit various tablet press models and different production requirements.
How is glove integrity tested and validated?
Automated glove testers check the gloves on a schedule. They use a pressure-decay or electronic leak test. The gloves also get a visual inspection, and the qualification is documented. WHO GMP guidance and ISO references set the test intervals and acceptance limits.
What is the standard configuration of a tablet compression isolator?
Fabtech supplies the isolator as an SS 316L chamber at negative pressure. The standard configuration has four glove ports on the main chamber, two on the pass box, and a glove integrity tester. Other chamber configurations are available.
What OEB bands can it handle?
Your compound sets the band, and your own occupational hygienist decides it. OEB 4 and OEB 5 are the bands usually named for potent products. Four things change between bands: the transfer method, the glove specification, the cleaning method and the testing. The OEL in micrograms per cubic metre matters more than the band itself.
How do tablets get out without breaking containment?
They leave through a split butterfly valve into IBC bins or polybags. The valve has two halves. Both halves stay closed until they are docked together. So the powder path is never open to the room.
Can the same isolator handle granulation or capsule filling?
Those are separate units in our range, because the machine inside is different. See the granulation isolator and the capsule filling isolator.
Send us your compound, its OEB band and your press model. We will plan the containment
We reply within 24 hours.